Performance Range:
Capacity up to 4.600 m3/h (20.250 USgpm)
Head up to 170 m (560 feet)
Speed up to 1750 min-1 (1750 r.p.m.)
Sizes:
DN 125 up to DN 600 (5” up to 24”) discharge
Size DN 32 up to DN 150 (11/4”up to 6”)
refer to design IC, brochure 7102.1.B
design LSN, brochure 1200.1.B
Temperature:
max. 180oC (350o F)
Casing pressure:
up to 16 bar (170/230 psig)
For higher casing pressures refer to design LC/LCP page 6
Handled liquids:
Clean or slightly contaminated liquids
(without bigger solids)
Cold and hot water
Condensate and deionate
Oil brine and acid
Paper stock suspensions up to 1,2%
Applications:
General industry
Chemical industry
Steel mills and mining
Sugar industry
Pulp and paper mills |
 |
Performance:
Capacity up to 450 m3/h (1980 USgpm)
Head up to 150 m (492 feet)
Speed up to 2950/3550 min-1 (2950/3550 rpm)
Pump Sizes:
DN 25 up to DN 150 (1“ up to 6“) Discharge
Casing Pressure:
up to 16 bar (235 psig)
Pump sizes 50-32-315, 65-40-315, 80-50-315, 100-65-315, 125-80-315
Liquids:
Clean and slightly contaminated fluids
(without bigger solids)
Cold and hot water
Condensate and VE water
Oil, brine, caustic and acid
Suspensions
Applications:
Water supply and water treatment
Cooling water supply
Hot water circulation
Materials:
Ductile iron - 0.7043
Stainless steel - 1.4408
Duplex - 1.4517
|
| |
|
 |
Performance range:
Capacities up to 340m3/h (1500 USgpm)
Head up to 500m (1640 feet)
Max. speed up to 3600 min-1 (3600 rpm)
Sizes:
DN 40 up to DN 125 (from 1 1/2“ to 5“)
discharge
Max. temperature:
140oC (280oF)
Max. casing pressure:
55 bar (800 psig)
Handled liquids:
Pure as well as slightly contaminated media
Applications:
water supply
booster systems
irrigation
fire fighting
snow making
cooling circuits
boiler feed
condensate
district heating
osmosis and ultra filtration.
|
 |
Performance Range:
Capacity up to 500 m3/h (2200 USgpm)
Head up to 45 m (150 feet)
Speed up to 1450 min-1 (1450 r.p.m.)
Sizes:
DN 65 up to DN 150 (21/2” up to 6”)
discharge
Temperature:
max. 120oC (250o F)
Casing pressure:
up to 10 bar (145 psig)
Liquids:
Contaminated liquids with solids
Waste water, sludge up to 8% atro
Suspensions, effluents, etc.
Raw, thick or thin juices
Applications:
Industrial or public waste and sewage plants
Chemical industry
Mining
Sugar mills
Pulp and paper mills. |
| |
|
|
| |
|